Effects of the Location of Heating Sources on Indoor Air Quality in Rural Buildings of Qingdao (China) in Winter as Determined by Experimental Monitoring

Author(s):

ORCID

Medium: journal article
Language(s): English
Published in: Buildings, , n. 3, v. 13
Page(s): 792
DOI: 10.3390/buildings13030792
Abstract:

In winter, many rural people in the coastal areas of northern China burn coal for both cooking and heating. As a result, the rural population is seriously affected by indoor air pollution. To analyze the influence of the location of heating sources on the air quality within rural buildings, 60 buildings with coal heating were surveyed and monitored using an Intelligent Built Environmental Monitor for eight days. In addition, four typical rural buildings with different locations of heating sources were selected for a transient analysis. The peak concentration of CO2 was 2869 ppm in House 1 with a coal-fired stove in the living room. The average particulate matter (PM) levels were 89 μg/m³, 150 μg/m³, and 182 μg/m³ for PM 1.0, PM 2.5, and PM 10, respectively, in House 2 where a stove was situated in a room adjacent to the living room. House 3, where stoves were in separate rooms, had PM 1.0, PM 2.5, and PM 10 values of 25 μg/m³, 39 μg/m³, and 49 μg/m³, respectively, and the lowest CO2 concentration (564 ppm) was found in House 4. The data collected showed that the CO2, PM 1.0, PM 2.5, and PM 10 concentrations within Houses 1 and 2 far exceeded the standard for indoor air quality. The findings suggested that coal-fired stoves, as a heating source, should be situated away from the living room and adjacent rooms, and this change would clearly reduce the concentrations of CO2 and particulate matter. Suitable courtyard ventilation was necessary for houses with two or more heating sources.

Copyright: © 2023 by the authors; licensee MDPI, Basel, Switzerland.
License:

This creative work has been published under the Creative Commons Attribution 4.0 International (CC-BY 4.0) license which allows copying, and redistribution as well as adaptation of the original work provided appropriate credit is given to the original author and the conditions of the license are met.

  • About this
    data sheet
  • Reference-ID
    10712788
  • Published on:
    21/03/2023
  • Last updated on:
    10/05/2023
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine