Effect of Microwave Pretreatment on the Properties and Microstructure of Low-Concentration Carbon Dioxide Early Cured Cement-Based Materials

Author(s):

ORCID
ORCID
Medium: journal article
Language(s): English
Published in: Buildings, , n. 4, v. 14
Page(s): 1074
DOI: 10.3390/buildings14041074
Abstract:

The utilization of microwave drying technology has expanded across various sectors due to its rapid processing speed, reduced operation time, lower sample temperatures, and consistent heating. In this research, microwave pretreatment was implemented prior to carbonation curing with low concentrations, and an array of tests including moisture content, compressive strength, carbonation depth, CO2 absorptivity, thermogravimetric analysis (TGA), X-ray diffraction (XRD), scanning electron microscopy (SEM), and mercury intrusion porosimetry (MIP) were utilized to investigate the effect of microwave pretreatment on the properties and microstructure of cementitious materials under early carbonation curing with low CO2 concentrations. The findings reveal that microwave pretreatment significantly decreases the moisture content within the test specimens, expediting the ingress of CO2 and improving the compressive strength of the specimens. At the same time, the effectiveness of microwave pretreatment in reducing moisture content diminishes as the pretreatment time increases. The absorption of CO2 is relatively rapid in the early stage of carbonation curing, with over 50% of the CO2 absorption occurring within the 0–6 h period of carbonation curing. The hydration products and microstructure of the uncarbonated part inside the specimens are generally consistent with the normal curing state. The formation of CaCO3 contributed to the densification of the specimen by infilling its internal voids, thereby enhancing its compressive strength. Although carbonation curing enlarges the average pore size of the samples, it also serves a filling function, making the samples more compact and reducing the porosity.

Copyright: © 2024 by the authors; licensee MDPI, Basel, Switzerland.
License:

This creative work has been published under the Creative Commons Attribution 4.0 International (CC-BY 4.0) license which allows copying, and redistribution as well as adaptation of the original work provided appropriate credit is given to the original author and the conditions of the license are met.

  • About this
    data sheet
  • Reference-ID
    10773439
  • Published on:
    29/04/2024
  • Last updated on:
    05/06/2024
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine