Loss of cable – design criteria for cable stayed bridges

 Loss of cable – design criteria for cable stayed bridges
Author(s): ,
Presented at IABSE Symposium: Challenges for Existing and Oncoming Structures, Prague, Czech Republic, 25-27 May 2022, published in , pp. 1763-1771
DOI: 10.2749/prague.2022.1763
Price: € 25.00 incl. VAT for PDF document  
ADD TO CART
Download preview file (PDF) 0.25 MB

In Cable stayed Bridge design a loss of a cable is an accidental /extreme event, that may govern the design of the superstructure, pylon, or the cables. The common design method is to use lineariza...
Read more

Bibliographic Details

Author(s): (SOFiN Consulting, Espoo, Finland)
(Finnish Transport Infrastructure Agency, Helsinki, Finland)
Medium: conference paper
Language(s): English
Conference: IABSE Symposium: Challenges for Existing and Oncoming Structures, Prague, Czech Republic, 25-27 May 2022
Published in:
Page(s): 1763-1771 Total no. of pages: 9
Page(s): 1763-1771
Total no. of pages: 9
DOI: 10.2749/prague.2022.1763
Abstract:

In Cable stayed Bridge design a loss of a cable is an accidental /extreme event, that may govern the design of the superstructure, pylon, or the cables. The common design method is to use linearization of the event by applying a dynamic amplification factor for the force effect. Another option is to perform dynamic analysis; however, the method is not standardized, widely used, nor is instructed in the standards.

Figure 1. New Kirjalansalmi Bridge, illustration.

Kirjalansami bridge in Parainen, Finland, is an old suspension bridge at the end of its service life. The bridge will be replaced by a new medium size of cable stayed bridge. In the preparation of the design basis, the phenomena of cable loss were studied by different methods. The aim of the study was to find reasonable requirements for the detailed design, so that the design will be reliable whilst not leading to too conservative design nor unnecessary cost increase. In this paper, the results of this study are presented.

Keywords:
stay cable dynamic analysis loss of cable Eurocodes Cable stayed bridges Dynamic amplification